Row Hams Resting

Information Request

The purpose of this system is to remove moisture from the product at low temperature, between 1C°and 4C°, without drying up the product's surface.

The system is available in a gravity circulation or ventilated version, depending on the type of product stored.

RESTING (GRAVITY CIRCULATION SYSTEM)

The system consists of:
- a set of ceiling-mounted gravity circulation evaporators with direct-expansion system;
- a set of vertically-positioned heating coils supplied with hot water.

The heating and cooling phases determine the degree of product drying and moisturizing.

Operation is managed and controlled by a microprocessor which programs the duration of the drying and moisturizing cycles.

RESTING ( VENTILATED SYSTEM)

The system is available in a "Turbo" and "Air diffuser" version.

The system includes:

1) An air treatment unit with:
- Refrigeration section with direct-expansion system;
- Heating section supplied with hot water or hot gas from the compressor;
- Ventilating section with ventilator coupled to motor via a pulley-belt coupling.

2) A set of air supply and return ducts.

The ducts have been carefully designed to ensure that temperature/humidity conditions are uniform throughout the room.

3) A programmable microprocessor for the management and control of all the operating parameters.

Operation is managed and controlled by a microprocessor which programs the duration of the drying and moisturizing cycles.